Web Enabled
Power Switch
V110120E
1. Table of Contents
2.
Important Safety Instructions………… 2
3.
General Description………..…………. 3
4.
Hardware Installation………..……….. 4
5.
Initial Configuration………..…………. 5
6.
Web Browser Operation………...…… 8
7.
Web Setup………..……………..……. 10
8.
Command Line Interface……..…...… 14
9.
DxP Protocol………..…………...…… 18
10.
Firmware Upgrades………..………... 18
11.
Troubleshooting………..……...…..… 19
12.
Specifications………..……………..… 20
13.
Technical Support and Warranty…… 21
Congratulations on purchasing the best network
controlled power switch available. The iBoot-G2
provides you the ability to reboot crashed
devices with the click of a mouse. Be sure to
read up on all the features of the iBoot-G2
Including:
Web Based setup and control
Telnet setup and control
Event Scheduling for real-time power
control.
AutoPing: Automatic monitoring and action
for failed equipment.
Management Utility: Easy Setup,
Firmware upgrades and Reset to Factory
Default
Easy Software Integration: Use the DxP
Protocol to build your own custom
applications
.
Seitenansicht 0
1 2 3 4 5 6 ... 20 21

Inhaltsverzeichnis

Seite 1 - 1. Table of Contents

Web Enabled Power Switch V110120E 1. Table of Contents 2.Important Safety Instructions………… 23.General Descript

Seite 2 - V110120E iBoot-G2 Page 2

V110120E iBoot-G2 Page 10 7. Web Setup iBoot-G2 setup section consists of several pages. Access any page via the buttons on the left of th

Seite 3 - 3. General Description

V110120E iBoot-G2 Page 11 7.3. AutoPing Introduction The AutoPing feature allows iBoot-G2 to automatically detect failed equipment and perf

Seite 4 - 4. Hardware Installation

V110120E iBoot-G2 Page 12 Action: Select from None AutoPing not used Power On – Latch Upon triggering, iBoot-G2 will power on and remain

Seite 5 - 4.3. Mounting Options

V110120E iBoot-G2 Page 13 Click Save to save the current settings. Click Clear to delete any current schedule. Note: All of the Schedule

Seite 6 - 5. Initial Configuration

V110120E iBoot-G2 Page 14 8. Command Line Interface The iBoot-G2 Command Line Interface (CLI) provides a text based method for communicating

Seite 7 - V110120E iBoot-G2 Page 7

V110120E iBoot-G2 Page 15 Network Commands All set commands require a reboot before they take effect. These commands are only available to t

Seite 8 - 6. Web Browser Operation

V110120E iBoot-G2 Page 16 and | or> relationship And or Or. set autoping action <none | on-latch | on-follow | off-latch | off-follow

Seite 9 - V110120E iBoot-G2 Page 9

V110120E iBoot-G2 Page 17 Prompts The CLI will use the following prompts: User> This prompts the user to enter his user name (user or ad

Seite 10 - 7. Web Setup

V110120E iBoot-G2 Page 18 9. DxP Protocol iBoot-G2 supports the Dataprobe Exchange Protocol (DxP) for inter device communications and to allo

Seite 11 - 7.4. AutoPing Settings

V110120E iBoot-G2 Page 19 11. Troubleshooting The iBoot-G2 has a recessed pushbutton switch in the event the unit is not performing as expec

Seite 12 - 7.5. Event Scheduling

V110120E iBoot-G2 Page 2 2. Important Safety Instructions When using this product, basic safety precautions should always be followed to red

Seite 13 - 7.6. Passwords

V110120E iBoot-G2 Page 20 12. Specifications 12.1. Physical Height 2.0” 60mm Width 3.2” 82mm Depth 4.2” 107mm Weight 8.6 oz 244g M

Seite 14 - 8. Command Line Interface

13. Technical Support and Warranty Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and operation of

Seite 15 - Autoping Commands

V110120E iBoot-G2 Page 3 3. General Description The iBoot-G2 is a network attached, IP addressed, web controlled AC power switch. Anyone wit

Seite 16 - Event Commands

V110120E iBoot-G2 Page 4 4. Hardware Installation 4.1. Ethernet Connections iBoot-G2 supports 10/100 Ethernet using the cable supplied, or

Seite 17 - Prompts

V110120E iBoot-G2 Page 5 4.3. Mounting Options iBoot-G2+ is suitable for desktop or shelf mounting. A mounting kit for wall and DIN rail mo

Seite 18 - 10. Firmware Upgrades

V110120E iBoot-G2 Page 6 5. Initial Configuration The Device Management Utility (DMU), available online at http://dataprobe.com/support/iboo

Seite 19 - 11. Troubleshooting

V110120E iBoot-G2 Page 7 Other ways to set the IP Address 1. Automatically from a DHCP Server 2. Web Browser via the Set-up Page 3. CLI (

Seite 20 - 12. Specifications

V110120E iBoot-G2 Page 8 6. Web Browser Operation 6.1. Password Protection iBoot-G2 uses two username/password credential sets, one for norma

Seite 21 - 13.1. WARRANTY

V110120E iBoot-G2 Page 9 To access the Setup page, the administrator credentials must be used for the initial login. When you are finished w